Lab Automation

Automated mobile phase and buffer preparation system

Automated mobile phase and buffer preparation for HPLC and tablet dissolution media.

Acculize MobiPhase One automated mobile phase and buffer preparation system for HPLC and dissolution media - view 1

The Acculize MobiPhase One is a lab automation system for mobile phase and buffer preparation in regulated QC and R&D chromatography laboratories. Buffer preparation, pH control, filtration and degassing run in one protocol-driven cycle.

It prepares mobile phases 3x to 5x faster than manual, depending on the method and complexity, and the analyst is free while the run completes.

The same buffer preparation system can also prepare buffers for tablet dissolution media, up to 10 L.

Key Features

  • Mobile phases 3x to 5x faster than manual, depending on the method and complexity
  • Also prepares buffers for tablet dissolution media, up to 10 L
  • Quick method transfer between R&D and Production
  • Analyst loads and retrieves; the run completes unattended
  • 0.1% error and RSD under 0.1% at 1000 mL
  • pH control within ±0.02 pH
  • Filtered and degassed, ready to use on completion
  • Designed for use in 21 CFR Part 11-regulated environments

One system, two applications

Mobile phase preparation for chromatography

Automated mobile phase prep for HPLC, UPLC and LC-MS: buffer preparation, solvent mixing, pH correction, filtration and degassing, ready to use on completion.

Buffer preparation for tablet dissolution media

Use the same buffer preparation system to prepare buffers for tablet dissolution media, up to 10 L, so one instrument can serve both your chromatography and dissolution work.

Manual mobile phase preparation is slow, variable and hard to audit

Slow

About 90 min to 135 min per mobile phase, before every sequence.

Error-prone

7 to 8 manual steps: weigh, dissolve, adjust pH, filter and degas.

Analyst-dependent

Manual RSD of about 1 to 2%, with variability across analysts and sites.

Wasteful

Excess volumes are prepared to avoid repeating the process, adding solvent and disposal burden.

Hard to audit

Paper logbooks and manual records create data integrity and audit exposure.

Unsafe

Operators are exposed to hazardous solvents.

Industry studies attribute up to 80% of process deviations to human error, with each deviation costing EUR 22,000 to 48,000. Source: PwC

Where the savings come from

Cost driverManualAcculize MobiPhase One
Analyst timeOccupied for the full preparationLoad and retrieve; free while the run completes
Solvents and buffersExcess batchesExact volume, on demand
Re-preparation and investigationsRecurringReduced by locked, repeatable protocols
ConsumablesMembrane filtersMembrane filters
MaintenanceNot applicableLocally serviceable components

On-demand, protocol-driven volumes mean exact preparation, minimal re-preparation caused by pH or ratio errors, lower disposal cost and lower operator exposure.

Four variants, one platform

5 L, single mixing

R&D, method development

5 L, dual mixing

R&D, higher throughput

10 L, single mixing

Production QC

10 L, dual mixing

Production QC, higher throughput

Dual mixing prepares Mobile Phase A and B in parallel, suited to gradient methods. All variants share the same software, protocols and validation package for easy methods transfer between R&D and QC teams. The system is configurable for different buffers, solvent systems and protocols without redesign.

See the chromatograms: Manual vs Acculize MobiPhase One

Request our pilot study report. It compares chromatograms of manual and Acculize MobiPhase One preparations for different molecules, with details of the buffer prepared, pH adjustment and solvent ratios.

Fields marked * are required.

Read how we approach data integrity on our Quality & Compliance page, or see our Acculize BET 96 Plus dry bath for 21 CFR Part 11-regulated LAL testing.

Technical Specifications

ApplicationsMobile phase and buffer preparation for HPLC, UPLC and LC-MS; buffers for tablet dissolution media, up to 10 L
Accuracy1000 mL: 0.1% error, RSD under 0.1%
pH controlWithin ±0.02 pH
WorkflowBuffer preparation, solvent mixing, pH correction, filtration and degassing
Preparation speed3x to 5x faster than manual, depending on the method and complexity
Variants5 L or 10 L, each with single or dual mixing (A and B in parallel)
SoftwareDesigned for use in 21 CFR Part 11-regulated environments: user access levels, e-signatures, audit trails, protocol locking, PDF reports, LIMS compatibility
IncludedInstallation, IQ/OQ documentation, training and warranty

Frequently Asked Questions

The Acculize MobiPhase One automates mobile phase and buffer preparation for regulated QC and R&D laboratories: buffer preparation, solvent mixing, pH correction, filtration and degassing, with electronic records of every step. The mobile phase is ready to use on completion.

Yes. The buffer preparation system within the Acculize MobiPhase One can prepare buffers for tablet dissolution media, up to 10 L. Labs that run both chromatography and dissolution testing can use one system for both.

The Acculize MobiPhase One prepares mobile phases 3x to 5x faster than manual preparation, depending on the method and complexity. The analyst loads and retrieves, and is free while the run completes.

At 1000 mL, it achieves 0.1% error with RSD under 0.1%, compared with a manual RSD of about 1 to 2%. pH is controlled to within ±0.02 pH.

Four variants on one platform: 5 L or 10 L, each with single or dual mixing. Dual mixing prepares Mobile Phase A and B in parallel, which suits gradient methods. All variants share the same software, protocols and validation package, so methods transfer between R&D and QC.

The Acculize MobiPhase One is designed for use in 21 CFR Part 11-regulated environments, with user access levels, e-signatures, audit trails, protocol locking and PDF reports. The software is GAMP 5 Category 4 (Configured Software). Regulatory compliance depends on the user's validated system and procedures; Acculize lab devices provide the technical controls and documentation to support it.

Yes. Request our pilot study report on this page. It compares chromatograms of manual and Acculize MobiPhase One preparations for different molecules.

Yes. Acculize Innovations is based in Chennai, India, and each unit includes installation, IQ/OQ documentation, training and warranty. Contact us for mobile phase automation and automated buffer prep for your lab, in India or abroad.

Each unit includes installation, IQ/OQ documentation, training and warranty. Book a demo to see a run and discuss your methods and volumes.

Have more questions?

Our technical experts are here to help you find the right solution for your laboratory.

Chat with us on WhatsApp