Acculize BET 96 Lite - View 1
Entry-Level Lab Equipment

Acculize BET 96 Lite

Acculize BET 96 Lite is a cost-effective incubation bath with 96 wells designed for LAL Endotoxin testing. Ideal for laboratories with basic testing needs requiring reliable temperature control and essential data management.

Key Features

  • Laser engraved 96-well format for high throughput testing
  • Basic control interface with Desktop software
  • PC Connectivity and Real-time temperature monitoring with alerts
  • Provision to take A4 printout of Temperature data logs
  • Standard temperature control for LAL BET testing
  • Superior Temperature Uniformity ± 0.2°C

Product Demo

Specifications:

Sample Capacity96 (10x75 mm LAL tubes)
Heating BlockAnodized aluminum with cast heater
MS Housing BlockMS powder-coated finish
Modular & Removable Heating BlockYes
Laser Engraved Well NumbersYes
PID-based temperature controllerYes
Temperature DisplayAccessible via desktop software (PC connectivity through USB)
Desktop ApplicationInterface with the heater unit for real-time monitoring and control
LAL ModePre-configured setting for LAL BET Gel Clot testing
Additional Pt 1000 Temperature SensorProvides protection for the heater and block in case of primary sensor failure
AlarmsBuzzer alerts for quick notifications
Temperature Resolution0.1°C
Temperature SensorPt 1000
Temperature Stability±0.3°C at 37°C (measured at 25°C RT)
Temperature Uniformity±0.2°C at 37°C (measured at 25°C RT)
Acrylic LidTransparent acrylic lid to securely cover the LAL tubes

Accessories

Custom Heating Blocks

Endotoxins come from Gram-negative bacteria, including E. coli, Salmonella, and Pseudomonas. The Acculize BET 96 Plus is compatible with all LAL tube sizes and configurations for broad-spectrum testing.We offer custom heating blocks designed to meet your specific laboratory requirements. Whether you need different well numbers, alternative well dimensions, or specialized configurations for your unique testing protocols, our engineering team can create tailored solutions.

Custom Options Available:

  • Different well numbers (24, 48, 192, or custom configurations)
  • Various well dimensions for different tube sizes
  • Specialized materials for specific applications
  • Custom laser engraving and numbering systems

Frequently Asked Questions

Bacterial endotoxin test (BET), often using the Limulus Amebocyte Lysate (LAL) assay, detects fever-causing endotoxins from Gram-negative bacteria. These tests are critical for pharmaceutical QC, ensuring products are safe and FDA-compliant for patient use.

Exposure can trigger fever, septic shock, and—in severe cases—organ failure. That’s why our BET 96 lite ensures sensitive detection in every batch.

The Acculize BET 96 Lite is designed for Bacterial Endotoxin Testing (BET) using the LAL Gel Clot method. It can accommodate 96 samples simultaneously, making it an ideal cost-effective solution for laboratories requiring reliable endotoxin testing with essential features.

The system operates with a temperature stability of ±0.3°C at 37°C and temperature uniformity of ±0.2°C at 37°C (measured at 25°C RT). It features a 0.1°C temperature resolution with PID-based temperature control for precise and consistent results.

The BET 96 Lite offers essential features for reliable endotoxin testing at a more affordable price point. While it maintains the same temperature accuracy and 96-well capacity, it provides core functionality through desktop software without some of the advanced features found in the Plus version.

The standard heating block accommodates 96 tubes of 10x75 mm LAL tubes. However, we offer custom heating blocks for different tube sizes and well configurations to meet your specific laboratory requirements.

The system connects to your computer via USB and comes with desktop software for real-time monitoring and temperature control. The software allows you to monitor the heating process and provides temperature display and control capabilities for your testing protocols.

The system includes essential safety features: an additional Pt 1000 temperature sensor for backup protection in case of primary sensor failure, buzzer alerts for quick notifications, and a transparent acrylic lid to securely cover the LAL tubes during testing.

The complete package includes the main heating unit with modular aluminum heating block (laser engraved well numbers), transparent acrylic protective lid, USB cable for PC connectivity, desktop software, user manual, and calibration certificate. Custom heating blocks are available separately.

Absolutely! The BET 96 Lite is specifically designed as a cost-effective solution for small to medium laboratories that need reliable endotoxin testing capabilities without compromising on quality. It provides excellent value while maintaining professional-grade performance.

We provide comprehensive warranty coverage and technical support. For specific warranty terms and support options, please contact our team. We also offer installation guidance, training, and ongoing technical assistance to ensure optimal performance of your system.

Yes! We offer product demonstrations and can arrange for trials at your facility. Contact us to schedule a demo or to discuss your specific requirements. Our technical team can provide hands-on training and support during the evaluation period.

Have More Questions?

Our technical experts are here to help you find the right solution for your laboratory needs.

Endorsements from Professionals

Biological E Limited Logo

QC Manager

Biologic E. Limited

The BET 96 Lite offers excellent value for labs with basic endotoxin testing needs. It's reliable, easy to use, and provides consistent results every time.